12:00 PM WE-CC-EXH C-1 |
A Versatile, Efficient and Inexpensive Phantom for IMRT Quality Assurance
- M. Urie, Y. Lo* |
12:00 PM WE-CC-EXH C-2 |
Commissioning and Quality Assurance of Precise-Plan TPS of Elekta.
- J. Avadhani*, H. Malhotra, J. Keane, M. Garg, S. Deore, V. Bhadrasain |
12:00 PM WE-CC-EXH C-3 |
Calibration of Well-type Chambers for Novoste 90Sr-90Y Intravascular Brachytherapy Source Trains
- M. Lambert*, J. Micka, L. DeWerd |
12:00 PM WE-CC-EXH C-4 |
In-vivo dose reconstruction using a transimission factor and an effective field concept
- Y. Kim*, I. Yeo |
12:00 PM WE-CC-EXH C-5 |
Comparison of the Head-Scatter Factors of the 6 MV beam for five different linear accelerators
- H. Malhotra*, J. Avadhani, M. Garg, S. Deore, B. Vikram |
12:00 PM WE-CC-EXH C-6 |
An image-based approach to measure ferric ion diffusion coefficient in an irradiated Fricke-infused dosimeter gel
- W. Chu*, Y. Tseng, S. Huang |
12:00 PM WE-CC-EXH C-7 |
Accuracy in the Presence of Inhomogenieties of Two Commercial Electron Planning Systems
- J. Lewis*, J. Beck, B. McCurdy, S. Pistorius |
12:00 PM WE-CC-EXH C-8 |
Transmission Factor of Lung Shielding used in TBI
- S. Gasiecki*, D. Boccuzzi, M. Podgorsak |
12:00 PM WE-CC-EXH C-9 |
Challenges in low energy photon dosimetery of a point source: Differences in international chamber calibrations and dose calculation protocols.
- A. Sliski*, K. Harte |
12:00 PM WE-CC-EXH C-10 |
Effect of Median Root Prior (MRP) regularization on the accuracy and convergence of a maximum likelihood expectation maximization algorithm applied to 3D scintillation dosimetry
- Z. Piao, A. Kirov* |
12:00 PM WE-CC-EXH C-11 |
Development and dosimetry of an 90Y plaque for irradiation of sarcomas of the spine
- T. Mauceri*, J. Beatty, G. Chen, T. DeLaney, F. Hornicek, J. Kung, J. Munro, H. Suit |
12:00 PM WE-CC-EXH C-12 |
Determination of organ motion and patient setup error using an in-line CT in external beam radiation treatment
- J. Mumper*, M. Bieda, D. Tilton, W. Lam, J. Chu |
12:00 PM WE-CC-EXH C-13 |
Prostate 3D-CRT Using Gradient-Distortion-Corrected MRI
- H. Shukla* |
12:00 PM WE-CC-EXH C-14 |
Modification of Treatment Couch for IMRT
- C. Saw*, K. Ayyangar, W. Zhen, C. Enke |
12:00 PM WE-CC-EXH C-15 |
An adaptive filtering technique for dynamic delivery of IMRT beams
- Y. Wu*, Q. Wu, R. Mohan |
12:00 PM WE-CC-EXH C-16 |
Comparing Algorithms for Optimizing Monitor Unit Settings along with Pencil Beam Transmissions in IMRT.
- M. Romesberg*, S. Zasadil, R. Hill, W. Tomer |
12:00 PM WE-CC-EXH C-17 |
Reduction of cardiac and lung complication probabilities after breast irradiation using conformal radiotherapy with and without intensity modulation
- C. Hurkmans*, J. Cho, L. Zijp, E. Damen, B. Mijnheer |
12:00 PM WE-CC-EXH C-18 |
A Preliminary Study of Reducing Dose Inhomogeneity in IMRT Optimization
- L. Wang*, L. Verhey, P. Xia |
12:00 PM WE-CC-EXH C-19 |
QA and the Gap Measurements for Dynamic IMRT
- M. Nikolic*, P. Higgins |
12:00 PM WE-CC-EXH C-20 |
Independent Monitor Unit Calculation for Serial Tomotherapy
- Z. Chen*, L. Xing, R. Nath |
12:00 PM WE-CC-EXH C-21 |
Use of THERAPLAN Plus Treatment Planning System for Quantitative Analysis in Endovascular Brachytherapy
- J. Cygler*, C. Angers, L. Eapen, M. Labinaz, J. Marquis, R. Bonan |
12:00 PM WE-CC-EXH C-22 |
Corrections for tumor and normal tissue dose in lung treatment based on Monte Carlo simulation using PENELOPE code
- P. DesRosiers*, V. Moskvin, C. Desrosiers, L. Papiez, R. Timmerman |
12:00 PM WE-CC-EXH C-23 |
Dose Calculation of Beamlets for IMRT using MCNP 4B Monte Carlo Code
- T. He*, F. Van den Heuvel |
12:00 PM WE-CC-EXH C-24 |
Monte Carlo Simulation for a Rotational Photon Beam
- J. Chow*, E. Wong, J. Chen, J. Van Dyk |
12:00 PM WE-CC-EXH C-25 |
Dose resolution of polymer gel dosimeters imaged by x-ray computed tomography
- J. Trapp, S. Bäck, M. Lepage, G. Michael, C. Baldock* |
12:00 PM WE-CC-EXH C-26 |
A Computerized Control System for a Neutron Multileaf Collimator
- J. Farr*, R. Maughan, J. Forman, M. Yudelev, E. Blosser, T. Horste |
12:00 PM WE-CC-EXH C-27 |
A Practical Analytically-Based Model for Total Activity-Volume Relationship for Ultrasound-Guided Transperineal Prostate Implants: Peripheral Loading Revisited
- P. Lee* |
12:00 PM WE-CC-EXH C-28 |
Monte Carlo dose parameters of the model LS-1 I-125 brachytherapy source
- R. Wang, R. Sloboda* |
12:00 PM WE-CC-EXH C-29 |
Study of tissue target volume ratio and other dosimetric indices as tools for treatment planning and evaluation of permanent prostate brachytherapy
- N. Sahoo* |
12:00 PM WE-CC-EXH C-30 |
Is an Ir-192 Permanent Seed Implant Feasible for Prostate Brachytherapy?
- G. Glasgow* |
12:00 PM WE-CC-EXH C-31 |
The Effect of Various Parameters on Photon Beam Peripheral Doses.
- C. Joshi*, A. Kerr, L. John Schreiner |
12:00 PM WE-CC-EXH C-32 |
Target Localization Using MRI and CT-MRI Image Fusion in Frameless Stereotactic Radiotherapy
- Y. Kang*, I. Choi, B. Choi, I. Kim, S. Park |
12:00 PM WE-CC-EXH C-33 |
Dosimetric comparison between a robot-based linac delivery and isocentric linac-based delivery for a complicate radiosurgery case
- A. Ho*, A. Lo, G. Luxton, J. Hai, A. Boyer |
12:00 PM WE-CC-EXH C-34 |
Examination of a Commercial Dental Mould as a Tissue Equivalent Bolus Material
- S. Babic, A. Kerr*, L. Schreiner |
12:00 PM WE-CC-EXH C-35 |
Robotic Variable SAD for Frameless Functional Radiosurgery
- T. Guerrero*, S. Chenery, I. Gibbs, J. Wang, D. Martin, C. Ma, J. Adler, Jr. |
12:00 PM WE-CC-EXH C-36 |
Use of a multileaf collimator to increase the field width achievable with a dynamic wedge
- I. Brezovich*, R. Popple, J. Duan |
12:00 PM WE-CC-EXH C-37 |
Radiosurgery with a motorized micro-multileaf-collimator: initial experiences in planning and commissioning
- M. Oldham*, C. Rowbottom, D. Jaffray |