Scientific Session
IMRT Verification
Wednesday 10:00:00 AM - 12:00:00 PM  Room: Ballroom 20B

Chair 1: Yan Chen, Thomas Jefferson University, Philadelphia, PA

Chair 2: Steven M. Morrill, UT Medical Branch, Galveston, TX, US

10:00 AM
WE-C20B-1
An Extensive Log-File Analysis of “step-And-Shoot” IMRT Subfield Delivery Errors - A. Stell*, J. Li, O. Zeidan, J. Dempsey
10:10 AM
WE-C20B-2
Validation of Dynamic MLC-Controller Log Files Using a Two-Dimensional Diode Array - J. Li*, J. Dempsey, L. Ding, C. Liu, J. Palta
10:20 AM
WE-C20B-3
A TAR-Based System for Automatic IMRT Dose Verification - S. Morrill*, J. Bayouth, D. Wendt
10:30 AM
WE-C20B-4
Intensity Modulated Stereotactic Radiotherapy Verification Using Monte Carlo Calculations and EPID Dosimetry - B. Parker*, H. Liu, A. Shiu
10:40 AM
WE-C20B-5
Monte Carlo Dose Calculation and Pre-Treatment Dose Verification for Highly Modulated Step and Shoot MLC Beams - A. Bakai*, M. Alber, M. Birkner, M. Fippel, F. Nuesslin
10:50 AM
WE-C20B-6
A Statistical Method for Analyzing and Verifying Dynamic and Static IMRT Delivery - L. Ma*, M. Sarfaraz, C. Yu
11:00 AM
WE-C20B-7
Dosimetric Consequences of IMRT On Moving Targets and Critical Structures - S. Goddu*, S. Nelson, A. Sharma, A. Turrisi
11:10 AM
WE-C20B-8
Dosimetric Analysis of the Effect of Respiration-Induced Lung Tumor Motion On Dynamic IMRT Treatments Using EDR2 Film - C. Pope*, R. Berbeco, S. Jiang
11:20 AM
WE-C20B-9
Dosimetric Evaluation of Step and Shoot Vs. Dynamic Micro-IMRT/ IMRS of Cranial Tumors - R. Mitra*, I. Das
11:30 AM
WE-C20B-10
IMRT Verification of Step-And-Shoot Delivery Using a Fast Scintillation Camera - O. Zeidan*, J. Li, M. Ranade, A. Stell, J. Dempsey
11:40 AM
WE-C20B-11
Dose Verification for Image-Guided Radiotherapy - J. Kapatoes*, K. Ruchala, G. Olivera, L. Forrest, M. Turek, T. Mackie, J. Welsh, H. Jaradat, J. Balog, W. Lu, R. Jeraj, P. Reckwerdt
11:50 AM
WE-C20B-12
The Measurement and the Significance of Critical Structure Doses in IMRT - Y. Zhang*, D. Korges, P. Kupelian, G. McNerney, P. Naplachowski, J. Pino-yTorres, C. Warner, T. Willoughby, D. Poole