Encrypted login | home

Program Information

Inherent Functional Dependence of Spinal Cord Doses of Variable Irradiated Volumes in Spine SBRT


L Ma

L Ma1*, S Braunstein1 , J Chiu1 , A Sahgal2 , (1) University of California San Francisco, San Francisco, CA, (2) Sunnybrook Health Sciences Center, University of Toronto, Toronto, Ontario

Presentations

SU-F-T-113 (Sunday, July 31, 2016) 3:00 PM - 6:00 PM Room: Exhibit Hall


Purpose: Spinal cord tolerance for SBRT has been recommended for the maximum point dose level or at irradiated volumes such as 0.35 mL or 10% of contoured volumes. In this study, we investigated an inherent functional relationship that associates these dose surrogates for irradiated spinal cord volumes of up to 3.0 mL.

Methods: A hidden variable termed as Effective Dose Radius (EDR) was formulated based on a dose fall-off model to correlate dose at irradiated spinal cord volumes ranging from 0 mL (point maximum) to 3.0 mL. A cohort of 15 spine SBRT cases was randomly selected to derive an EDR-parameterized formula. The mean prescription dose for the studied cases was 21.0±8.0 Gy (range, 10-40Gy) delivered in 3±1 fractions with target volumes of 39.1 ± 70.6 mL. Linear regression and variance analysis were performed for the fitting parameters of variable EDR values.

Results: No direct correlation was found between the dose at maximum point and doses at variable spinal cord volumes. For example, Pearson R² = 0.643 and R²= 0.491 were obtained when correlating the point maximum dose with the spinal cord dose at 1 mL and 3 mL, respectively. However, near perfect correlation (R² ≥0.99) was obtained when corresponding parameterized EDRs. Specifically, Pearson R²= 0.996 and R² = 0.990 were obtained when correlating EDR (maximum point dose) with EDR (dose at 1 mL) and EDR(dose at 3 mL), respectively. As a result, high confidence level look-up tables were established to correlate spinal cord doses at the maximum point to any finite irradiated volumes.

Conclusion: An inherent functional relationship was demonstrated for spine SBRT. Such a relationship unifies dose surrogates at variable cord volumes and proves that a single dose surrogate (e.g. point maximum dose) is mathematically sufficient in constraining the overall spinal cord dose tolerance for SBRT.


Contact Email: