Encrypted login | home

Program Information

GPU-Monte Carlo Based Fast IMRT Plan Optimization

no image available
Y Li

Y Li*, Z Tian , F Shi , S Jiang , X Jia , The University of Texas Southwestern Medical Ctr, Dallas, TX

Presentations

TH-E-BRE-8 Thursday 1:00PM - 2:50PM Room: Ballroom E

Purpose:Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow.

Methods:A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final result.

Results:For a lung case with 5317 beamlets, 10⁵ particles per beamlet in the first round, and 10⁸ particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec.

Conclusion:A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.


Contact Email: