Encrypted | Login
HyTEC 2116 - Radiation Dose-Volume Effects for Liver SBRT (2017)

Category: HyTEC

A quantitative review of published data on radiationinduced liver and gastrointestinal (GI) normal tissue toxicities in liver stereotactic body radiation therapy (SBRT) is performed. The report presents normal tissue dose-response parameters, recommendations for dose-volume limits for liver SBRT, and outlines standards for future reporting of liver and GI dosimetric and clinical data.

Supplemental Materials 1


International Journal of Radiation Oncology*Biology*Physics
https://doi.org/10.1016/j.ijrobp.2017.12.290


Moyed Miften, PhD, Yevgeniy Vinogradskiy, PhD, Vitali Moiseenko, PhD, Jimm Grimm, PhD, Ellen Yorke, PhD, Andrew Jackson, PhD, Wolfgang A. Tomé , PhD, Randall K. Ten Haken, PhD, Nitin Ohri, MD, Alejandra Méndez Romero, MD,# Karyn A. Goodman, MD, Lawrence B. Marks, MD, Brian Kavanagh, MD, and Laura A. Dawson, MD

DISCLAIMER
I Disagree
I Agree

Show list of all AAPM HyTec Reports »