Task Group No. 66U1 - Quality assurance for computed-tomography simulators in Radiation Oncology: An Update to the Report of the AAPM Radiation Therapy Committee Task Group No. 66 (TG66U1)

AAPM Members, Affiliates and Non-Member Affiliates - Login for access to additional information

Activities
  1. Provide a concise update of the AAPM TG-66 report “Quality assurance for computed-tomography simulators and the computed-tomography-simulation process” that reflects the major advances in CT simulator technology, new knowledge, and practice changes since the original 2003 report.
  2. Review and provide comprehensive guidelines for acceptance testing, commissioning, and periodic quality assurance of CT simulators used for Radiation Oncology treatment planning purpose with focus on technologies not addressed in the original report that have since become common practice. These technologies include 4D-CT for respiratory gating, dual/multi-energy CT, metal-artifact reduction techniques, extended HU scales, and extended field-of-view reconstructions.
  3. Provide guidelines for creating scan protocols specifically for CT simulators and discuss differences to diagnostic CT scan protocols.
  4. Identify common fault trees in the CT simulation process and provide examples for TG-100-style prospective quality management for CT simulators.
By-Laws:Not Referenced.Rules: Not Referenced.
Standing?This is not a standing committee.
Approved Date(s):6/25/2021 - 12/31/2025
Reviewable Draft Deadline:
Committee Keywords: No Keywords Entered

Board of Directors
Science Council
Therapy Physics Cmte  [Status]
Therapy Imaging SC  [Status]
Imaging for Treatment Planning  [Status]
TG66U1 - Quality assurance for computed-tomography simulators in Radiation Oncology: An Update to the Report of the AAPM Radiation Therapy Cmte TG66  [Status]

» Conflict of Interest report for TG66U1
» Status Reports for Task Groups - AC | EC | IC | PC | SC | Board Committees | All
Chairs

Jochen Cammin
Task Group Co-Chair

Heng Li
Task Group Co-Chair

2025 Roster

(dates shown below are start and end dates of position.)

= complete and up-to-date
= up-to-date but expires soon
= incomplete or out of date conflict of interest statement.

VOTING AppointmentsThere are 10 voting members.

up-to-dateJochen Cammin, PhD

6/25/2021 - 12/31/2025 Task Group Co-Chair

up-to-dateIndra J. Das, PhD

6/25/2021 - 12/31/2025 Member

up-to-dateM. Saiful Huq, PhD

6/25/2021 - 12/31/2025 Member

up-to-dateShuai Leng, PhD

6/25/2021 - 12/31/2025 Member

up-to-dateHeng Li, PhD

6/25/2021 - 12/31/2025 Task Group Co-Chair

up-to-dateQihui Lyu, PhD

11/15/2023 - 12/31/2025 Member

up-to-dateJessica R. Miller, PhD

6/25/2021 - 12/31/2025 Member

up-to-dateDouglas E. Prah, PhD

8/17/2021 - 12/31/2025 Member

up-to-dateMihaela Rosu-Bubulac, PhD

6/25/2021 - 12/31/2025 Member

up-to-dateHao Zhang, PhD

8/1/2021 - 12/31/2025 Member
NON-VOTING AppointmentsThere are 4 non-voting members and guests.

up-to-dateHao Dang, PhD

8/17/2021 - 12/31/2025 Consultant - Philips (nonvoting)

up-to-datePriti Madhav, PhD

12/31/1969 - 12/31/2025 Consultant - GE (nonvoting)

up-to-dateKenneth J. Ruchala, PhD

8/17/2021 - 12/31/2025 Consultant - Sun Nuclear (nonvoting)

up-to-dateJainil Shah, PhD

6/25/2021 - 12/31/2025 Consultant - Siemens (nonvoting)
HQ Team Appointed to CommitteeThere are 0 staff.



See connections to Task Group No. 66U1 - Quality assurance for computed-tomography simulators in Ra